V – system settings/statistics – Westermo TD-34 User Manual

Page 33

Advertising
background image

33

6610-2203

&V – System settings/statistics

&V0 – Display Current Configuration and Stored Profiles Reports the current (active)
configuration, the stored (user) profiles, and the first four stored telephone numbers.
The stored profiles and telephone numbers are not displayed if the NVRAM is not
operational as detected by the NVRAM test during reset processing.

ACTIVE PROFILE:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &K3 &Q5 &R1 &S0 &T4
&X0 &Y0 S00:002 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:030
S08:002 S09:006 S10:014 S11:255 S12:050 S18:000 S25:005 S26:001 S36:007
S37:000 S38:020 S46:138 S48:007 S95:000

STORED PROFILE 0:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &K3 &Q5 &R1 &S0 &T4
&X0 S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050
S18:000 S36:007 S37:000 S40:105 S41:003 S46:138 S95:000

STORED PROFILE 1:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &K3 &Q5 &R1 &S0 &T4
&X0 S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050
S18:000 S36:007 S37:000 S40:105 S41:003 S46:138 S95:000

TELEPHONE NUMBERS:
0 =

1 =

&V1 – Displays the last connection statistics in the following format

(shown with typical results):

TERMINATION REASON

..........................

LOCAL REQUEST

LAST TX rate

....................................

33 600 BIT/S

HIGHEST TX rate

...............................

33 600 BIT/S

LAST RX rate

....................................

33 600 BIT/S

HIGHEST RX rate

...............................

33 600 BIT/S

PROTOCOL

...........................................

LAPM

COMPRESSION

......................................

V42Bis

Line QUALITY

....................................

033

Rx LEVEL

...........................................

015

Highest Rx State

.............................

67

Highest TX State

.............................

67

EQM Sum

.............................................

00C2

RBS Pattern

......................................

FF

Rate Drop

.........................................

FF

Digital Pad

......................................

None

Local Rtrn Count

.............................

00

Remote Rtrn Count

...........................

00

Flex fail

RBS Pattern:

Shows the number of least significant bits robbed per 6 bytes.

Digital Pad:

Shows if a pad was encountered and if so, what was the digital loss.

Flex:

Shows V.8bis information as follows:

First byte:

Octet 13 (second byte of manufacturer id, 94 = K56flex)

Second byte:

Octet 14 (Licensee code: 81 = Rockwell)

Third byte:

Octet 15 (manufacturer's product capabilities)

Fourth byte:

Octet 16 (K56flex version number)

Fifth byte:

Octet 17 (Rockwell pump code version number)

Sixth byte:

Octet 18 (x-law and controller version number)

Bit 4:

0 Controller version

Syntax:

AT&V<value>
<value>

= 0 System settings
= 1 Last connection statistics

Examples:
Result Codes:

OK

<value> = (0-1)

ERROR

Otherwise

Advertising