*WIOL – General IO list

This command set IO list entries with parameters and data.

Syntax:
AT*WIOL=<entry>,<service>,<flag>,<timeout>,<priority>,<data1>,<data2>

AT*WIOL=?
AT*WIOL?
<entry>

IO entry number

<service>

IO entry service(0=NONE, 1=DIAL, 2=SMS, 3=TEXT,
4=EMAIL, 5=OUT, 6=CMD, 7=TRANS)

<flag>

IO retry
(0=NO, 1=RETRY, 2=RETRY_3, 3=NEXT_OK,
4=NEXT_ERR)

<timeout>

IO timeout (0=NO, 1-255=MINUTES)

<priority>

IO timeout (0=NO, 1=PRIORITY)

<data1>

IO entry data field 1

<data2>

IO entry data field 2

Examples:

AT*WIOL =1,2,2,0,12345,ABCDEFG
OK
AT*WIOL?
# SERVICE

FLAG

TIME

PRI

DATA1

DATA2

1 DIAL

NO

000

0

12345

2 SMS

RETRY_3 000

1

12345

3 NONE

NO

000

0

4 NONE

NO

000

0

5 NONE

NO

000

0

6 NONE

NO

000

0

7 TEXT

RETRY

005

1

123

ABC

8 NONE

NO

000

0

OK
AT*WIOL=?
*WIOL : (1-8),(0-7),(0-4),(0-255),(0,1),(0-16 CHAR), (0-40 CHAR),
OK

Result Codes: OK

<entry>,<service>,<flag>,<timeout>,<priority>,
<data1>,<data2> =(1-8),(0-7),(0-4),(0-255),(0,1),
(0-16 Characters) ,(0-40 Characters)

ERROR

Otherwise