ERROR MESSAGE

When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems with
one or more channels. “XX” stands for channel 1,5,6,8,9 who has the testing sensor for positioning .
For example, when the display shows “01Er”, it means there is some error in channel 1. If there are some errors on
channel 1, channel 5, channel 6 at the same time, you may see the error message “01Er”, “05Er”,”06Er” flash
repeated for 5 times, and then the fixture will generate a reset signal, all the stepper reset. If the fixture remain error
message after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors. If the
fixture has more than 3 errors (including 3 errors), all the channels can not work properly; but if the fixture has less
than 3 errors, only the channels which have errors can not work properly, others can work as usual.

01Er:
(Color-wheel 1 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The color wheel is not located in the default position after the reset.

05Er:
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The yoke is not located in the default position after the reset.

06Er:
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The head is not located in the default position after the reset.

08Er:
(Effect-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main
PCB). The rotating gobo is not located in the default position after the reset.

09Er:
(Zoom error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The zoom
is not located in the default position after the reset.

CLEANING AND MAINTENANCE

The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must

not be corroded.

2) There must not be any deformations on the housing, color lenses, fixations and installation spots

(ceiling, suspension, trussing).

1) Mechanically moved parts must not show any traces of wearing and must not rotate with

unbalances.

2) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.

Note:

If the external flexible cable or cord of this device is damaged, it shall be exclusively

replaced by the manufacturer or his service agent or a similar qualified person in order to avoid