ECHO E ON ON/OFF Activates echo back of your keystrokes on the

computer screen

3-2-4

EPATH EPATH

N/A

Call1, --,
Call7

Sets digipeater list to be replaced while using
UISSID

8-3-9

EXTCLR EXTC N/A N/A Clears

the

Message

Board

10-1-6

FILE FI N/A N/A Displays all messages on the Message Board.

10-2-1

FIRMRNR FIR OFF ON/OFF In RNR frame reception, TNC waits to transmit

until next frame reception.

4-4-11

FLOVER FL

0 0-120 Sets time when the TX/RX buffers are cleared after

the host’s buffer has filled up. A unit of 1mS.

3-2-8

FLOW F ON ON/OFF When on, when you start keyboard activity, TNC

output to the terminal stops.

3-2-5

FRACK FR 3 0-15 The re-try waiting period in units of 1 second.

4-4-7

FULLDUP FU OFF ON/OFF To select Full-Duplex or Semi- Duplex mode. Not

useful in a monoband transceiver

4-2-9

GBAUD GB 4800 4800/9600 Sets the data communication rate with the GPS

receiver

5-6-1

GPSSEND GPSS N/A 159

characters

Use to output up to 159 characteristics to initialize
the GPS. This data cannot be memorized.

5-6-10

GPSTEXT GPST $PNTS 6

characters Sets the data string to be sent into LTEXT from the

GPS.

5-6-6

HBAUD HB 1200 1200/9600 Changes the data rate of communications over the

radio (1200 or 9600bps)

4-1-1

HEALLED HEAL OFF ON/OFF Tests LEDs on TNC

7-5-1

HID HI ON ON/OFF When ON, sends ID after packets are digipeated

through your station

8-1-3

ID I N/A N/A Transmits ID immediately.

8-1-4

KILL KI ON ON/OFF Deletes Messages on the message board

10-2-6

KISS KISS OFF ON/OFF TNC will enter the KISS mode after the next

boot-up.

6-5-1

LCSTREAM LCS ON ON/OFF Allows lower case letter to be used after stream

switch command is sent

9-1-4

LIST LI N/A N/A Displays all messages except private messages

being sent from one station to another

10-2-2

LOCATION LOC EVERY

0 EVERY/AF

TER
n(0-250)

Sets the time interval of GPS data transmissions
(stored in LTEXT) in 10 second increments.

5-6-3

LOG LOG N/A N/A Displays a list of stations that connected to the

Message Board.

10-1-7

LPATH LPA GPS Call

(VIA

call1,call2
,--,call8)

Sets the outgoing path of GPS data. (Including
DIGIpeater(s) used).

5-6-2

LTEXT LT N/A 159

characters

The GPS data buffer.

5-6-4

LTMON LTM 0

0-250 Displays the LTEXT message as if it were received

as a beacon signal, in preset intervals.

5-6-5

MAIL

MAI

OFF

ON/OFF

When ON, LED indicates when messages are
received

10-3-3

MALL

MA

ON

ON/OFF

Monitor all stations/not connected stations

4-7-4

MAXFRAME MAX

4

1-7

The maximum number of packet frames the unit
can transmit at once

4-6-7

MBOD

MB

OFF

ON/OFF

Enables use of Message Board

10-1-1

MCOM

MCOM

OFF

ON/OFF

TNC monitors all I frames.

4-7-2

MCON

MC

OFF

ON/OFF

Monitor (or not monitor) other stations while you
are connected.

4-7-3

MINE

MI

N/A

N/A

Displays the list of messages addressed to my
callsign from the Message Board.

10-2-3