1.1.3.1 000F-0001-0003 2014/04/01 12:12:12 12 Up

2.

Verify the configuration on Switch B:
# Display information about the EVI tunnel interface.

[SwitchB] display interface tunnel 0

Tunnel0

Current state: UP

Line protocol state: UP

Description: Tunnel0 Interface

Bandwidth: 64kbps

Maximum Transmit Unit: 64000

Internet protocol processing: disabled

Tunnel source 1.1.2.1

Tunnel keepalive enabled, Period(20 s), Retries(2)

Network ID 1

Tunnel protocol/transport GRE_EVI/IP

Last clearing of counters: Never

Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Input: 0 packets, 0 bytes, 0 drops

Output: 0 packets, 0 bytes, 0 drops

# Display information about EVI-Link interfaces.

[SwitchB] display evi link interface tunnel 0

Interface Status Source Destination

EVI-Link0 UP 1.1.2.1 1.1.1.1

EVI-Link1 UP 1.1.2.1 1.1.3.1

# Display ENDC information.

[SwitchB] display evi neighbor-discovery client summary

Status: I-Init E-Establish P-Probe

Interface Local Address Server Address Network ID Reg Auth Status

Tunnel0 1.1.2.1 1.1.1.1 1 15 disabled E

# Display neighbor entries that Switch B has learned.

[SwitchB] display evi neighbor-discovery client member

Interface: Tunnel0 Network ID: 1

Local Address: 1.1.3.1

Server Address: 1.1.1.1

Neighbor System ID Created Time Expire Status

1.1.1.1 000F-0001-0001 2014/04/01 12:12:12 13 Up

1.1.3.1 000F-0001-0003 2014/04/01 12:12:12 13 Up

3.

Verify the configuration on Switch C:
# Display information about the EVI tunnel interface.

[SwitchC] display interface tunnel 0

Tunnel0

Current state: UP

Line protocol state: UP

Description: Tunnel0 Interface

Bandwidth: 64kbps

Maximum Transmit Unit: 64000