Bfd packet format – H3C Technologies H3C SR8800 User Manual

Page 113

Advertising
background image

104

SHA1—SHA1 (Secure Hash Algorithm 1) authentication

NOTE:

BFD authentication is not supported on the router.

BFD packet format

BFD control packets are encapsulated into UDP packets with port number 3784 for single-hop detection

or port number 4784 for multi-hop detection (also can be 3784 based on the configuration task). BFD

echo packets have a similar format as BFD control packets (except that the Desired Min TX Interval and

Required Min RX Interval fields are null) with UDP port number 3785.

Figure 31 BFD packet format

Vers—Protocol version. The protocol version is 1.

Diag—This bit indicates the reason for the last transition of the local session from up to some other
state.

Table 9

lists the states.

Table 9 Diag bit values

Diag Description

0 No

Diagnostic

1

Control Detection Time Expired

2

Echo Function Failed

3

Neighbor Signaled Session Down

4

Forwarding Plane Reset

5 Path

Down

6 Concatenated

Path

Down

7 Administratively

Down

8

Reverse Concatenated Path Down

9~31

Reserved for future use

State (Sta)—Current BFD session state. Its value can be 0 for AdminDown, 1 for Down, 2 for Init,
and 3 for Up.

Poll (P)—If set, the transmitting system is requesting verification of connectivity, or of a parameter
change. If clear, the transmitting system is not requesting verification.