29

Binding RPR physical ports with an RPR logical interface in RPR logical interface view

To bind RPR physical ports with an RPR logical interface in RPR logical interface view:

Step

Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter RPR logical interface
view.

interface rpr interface-number N/A

3.

Bind a physical port with the
RPR logical interface.

rpr bind { { rprpos | rprxge }
interface-number
} { ringlet0 |

ringlet1 }

By default, no RPR physical ports
are bound with an RPR logical

interface.

Binding RPR physical ports with an RPR logical interface in RPR physical port view

To bind RPR physical ports with an RPR logical interface in RPR physical port view:

Step

Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter RPR physical port view.

interface { rprpos | rprxge }
interface-number

N/A

3.

Bind the RPR logical interface

with the physical port.

rpr bind { rpr interface-number }
{ ringlet0 | ringlet1 }

By default, no RPR physical ports
are bound with an RPR logical
interface.

Enabling RPR mate port smart connection

For an RPR station to forward traffic, before binding its two RPR physical ports with the same logical RPR

interface, you must connect their mate ports.
When the two RPR physical ports are on the same subcard (centralized RPR), you can enable the RPR

mate port smart connection function. With the function enabled, RPR automatically connects the two

mate ports without you having to connect them manually.
To enable RPR mate port smart connection:

Step

Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter RPR logical interface

view.

interface rpr interface-number

N/A

3.

Enable RPR mate port smart
connection.

rpr mate smart-connect

Disabled by default.

Changing the RPR physical port type

To change the RPR physical port type on an RPR logical interface:

Step Command