Logging in to the access controller module – H3C Technologies H3C LSWM1WCM10 Access Controller Module User Manual

Page 20

Advertising
background image

13

Logging in to the access controller module

NOTE:

Because the LSWM1WCM10 and LSWM1WCM20 do not have console ports, you can only redirect to
them from switches.

Logging in to the access controller module directly

When the first connection method described in “

Setting up a configuration environment

” is used, the

serial port of the PC is connected to the console port of the access controller module and you can directly

log in to the access controller module through the HyperTerminal on the PC.

Redirecting to the access controller module from the switch

Before you redirect to an access controller module from the switch, make sure the AUX port on the access

controller module is in none authentication mode, which is the factory defaults. For how to configure an
AUX port in none authentication mode, see

Table 3

.

Table 3 Configure the AUX port in none authentication mode

To do…

Use the command…

Remarks

Enter AUX port user interface view

user-interface aux first-number
[ last-number ]

Configure the AUX port in none
authentication mode

authentication-mode none

Optional
By default, the authentication
mode for an AUX port is none.

Set the command level for the user
to access

user privilege level level

Optional
Level 3 by default.

When the second connection method described in “

Setting up a configuration environment

” is used, the

serial port of the PC is connected to the console port of the switch. After logging in to the switch through

the HyperTerminal, you can redirect to the access controller module from the switch by performing the

following operations.
After you redirect to the operating system of the access controller module from the switch, the displayed

interface is switched from the CLI of the switch to the operation interface of the access controller module,

so that you can manage the access controller module.
After the interface switchover, you can return to the CLI of the switch by pressing Ctrl+K.

Table 4 Redirect to the access controller module from the switch

To do…

Use the command…

Remarks

Redirect to the access controller
module from an S7500E switch

oap connect slot slot-number

Required
Available in user view of the
switch

Redirect to the access controller

module from an S5800 switch

oap connect slot slot-number system

system-name

Required
Available in user view of the

switch

Advertising