8937/8937D Instruction Manual

Power Up

Power Up

The front LED indicators and configuration switches are illustrated for the
8937 in

Figure 7

. The 8937D module has an addition row of identical LEDs

labeled for DA 1 and DA 2. Upon power-up, the green PWR LED should
light and the yellow CONF LED should illuminate for a few seconds for the
duration of module initialization.

Figure 7. LEDs and Configuration Switches

Operation Indicator LEDs

Refer to

Figure 7

and

Table 2

for the name and meaning of each of the board

edge operating indicators on the module circuit board.

Table 2. Board Edge LED Names and Meaning

LED

8937

8937D

Condition

DA 1

DA 2

FAULT

(red)

Off

Off

Off

Normal operation.

On continuously

On

On

Module has detected an internal fault. (Refer to

Functional Description

on page 30

.)

Long Flash

Long Flash

Long Flash

Input missing or input does not match bit rate set with manual mode.

COMM

(yellow)

Off

Off

Off

No activity on frame communication bus.

3 Quick Pulses

3 Quick

Pulses

3 Quick

Pulses

Locate Module command received by the module from a remote control system.

Short flash

Short flash

Short flash

Activity present on the frame communication bus.

CONF

(yellow)

Off

Off

Off

Module is in normal operating mode.

On continuously

On

On

Module is initializing, changing operating modes or programming hardware.

PWR

(green)

Off

Off

Off

No power to module or module’s DC/DC converter failed.

On

On

On

Normal operation, module is powered.

GRASS VALLEY 8937D SDI RECLOCKING EQ SNMP DA

8937

8270_05

FAULT (red)

COMM (yellow)

CONF (yellow)

PWR (green)

SIG PRES

143Mb

BYPASS

177Mb

270Mb

360Mb

REM OVR

Advertising
This manual is related to the following products: