8937/8937D Instruction Manual

15

Power Up

Table 3

provides the various output conditions possible for a given input

and module setting.

SIG PRES

(green)

Off

Off

Off

No signal input detected or input signal does not match bit rate set with manual
mode.

On

On

On

In Auto or Bypass mode input signal is present or input signal matches bit rate set
with manual mode.

BYPASS
(yellow)

Off

Off

Off

Reclocking is enabled and auto-rate detection mode is active.

On

On

On

Bypass mode is on, input signal will not be reclocked

143 Mb

(yellow)

Off

Off

Off

No 143 Mb speed signal present.

On

On

On

Input signal is locked at 143 Mb

177 Mb

(yellow)

Off

Off

Off

No 177 Mb speed signal present.

On

On

On

Input signal is locked at 177 Mb

270 Mb

(yellow)

Off

Off

Off

No 270 Mb speed signal present.

On

On

On

Input signal is locked at 270 Mb

360 Mb

(yellow)

Off

Off

Off

No 360 Mb speed signal present.

On

On

On

Input signal is locked at 360 Mb

REM OVR

(yellow)

Off

Off

Off

Module setting match those set on module switches and jumpers.

On

On

On

Remote control is overriding on-board jumper setting

Table 3. Possible Output Conditions

Input

Setting

Output Condition

Standard definition SDI video

Auto or Bypass

Standard definition SDI video

Other carrier

Bypass

Other carrier

Other carrier

Auto

Signal with errors

No signal or over EQ range

All modes

Muted

Table 2. Board Edge LED Names and Meaning