8964MON Instruction Manual

Power Up

Table 2. Board Edge LED Names and Meaning

LED

Indication

Condition

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault. (Refer to

Service

on page 34

.)

Flashing

Configuration problems. Check inputs and settings. Missing video.

COMM

(yellow)

Off

No activity on frame communication bus.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

Short flash

Activity present on the frame communication bus.

CONF

(yellow)

Off

Module is in normal operating mode.

On continuously

Module is initializing, changing operating modes or programming hardware.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

525/625

(green)

Off

Not Used

CM1

(yellow)

Off

On/Off combination Indicates what channel is enabled for configuration when
Channel Select Mode (CSM) LED is on (described in

Table 4 on page 16

).

On

CM0

(yellow)

Off

On

CH1

(green)

Off

No signal present on Channel 1.

On continuously

Valid signal is present on Channel 1.

CH2

(green)

Off

No signal present on Channel 2.

On continuously

Valid signal is present on Channel 2.

CH3

(green)

Off

No signal present on Channel 3.

On continuously

Valid signal is present on Channel 3.

CH4

(green)

Off

No signal present on Channel 4.

On continuously

Valid signal is present on Channel 4.

2ND

(yellow)

Off

Not Used

CSM

(yellow)

Off

Paddle switch controls current Bank parameter mode.

On continuously

Paddle switch controls channel selection.