Grass Valley 8964MON User Manual

Page 30

Advertising
background image

30

8964MON Instruction Manual

Configuration

Slot Config Web Page

Use the Slot Config web page (

Figure 16 on page 31

) to perform the fol-

lowing functions on the 8964MON module:

Locate Module

– selecting

Flash

from the

Locate Module

pulldown flashes

the yellow COMM and CONF LEDs on the front of the module so it can
be located in the frame.

Slot Identification

– You may type a specific name in the

Name

field The

assigned name is stored on the 8900NET module and travels with the
8900NET module if it is moved to another frame. Select

Default

to enter

the factory default module name.

An asset identifier may be entered into the

Asset Tag

field for inventory

purposes (functionality requires 8900NET software 3.2.2 or later). The
asset tag will appear on the Status web page and can be used in the
Inventory function with the NetConfig Network Configuration appli-
cation.

Slot Memory

– the slot configuration for each media module is automati-

cally saved periodically (once an hour) to the 8900NET module in that
frame. You may also select the

Learn Module Config

button at any time to

save the current configuration for this slot. The configuration is saved
on the 8900NET module. If the 8900NET module is removed or
powered down, the stored configurations are not saved.

When the

Restore upon Install

box has been checked, the current configu-

ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type is installed,
the configuration saved to the 8900NET module will be downloaded to
the new module. The box must be checked before the current module
with the saved configuration is removed.

Hardware Switch Controls

– a read-only status report of 8900NET module

switch settings for Module Status Reporting and Asynchronous Status
Reporting. These functions must be enabled for the following Slot
SNMP Trap Reports to function.

Frame Heath Reporting

– this function is not used on the current version of

8900NET software which controls this page.

Slot SNMP Trap Reports

– displayed only when the SNMP Agent software

has been installed on the 8900NET module. Slot SNMP traps can be
enabled only when the hardware switches for Module Fault reporting
and Asynchronous Status reporting are enabled on the 8900NET
module (dipswitch S1 segment 5 and dipswitch S2 segment 1).

The enabled SNMP traps will be reported to any SNMP manager that
is identified as an SNMP Report Destination in 8900NET configuration.
Trap severity is read-only hard-coded information that is interpreted
and responded to by the SNMP Manager software configuration.

Use
this
link