Configuring Loudness Analysis Parameters

46

Configurable loudness analysis parameters

Parameter

name

Description

Data set

Standard

The program compliance loudness standard against which the loudness data will be
measured.

EBU G8 refers to the now-obsolete version of EBU-R128 recommending a gate value

of -8LU. The currently recommended value is -10LU.

A85 1770-1 leaves the threshold level up to broadcasters and recommends an

anchor when available and a gate if necessary (used in USA, Canada).

A85 1770-2 recommends a gate is ALWAYS enabled, having a threshold set to -10LU

(used in the European Union).

ARIB TR-B32 is based on A85 1770-2 with a recommended threshold of -24LKFS

(absolute gate at -70LKFS, -10LU relative gate, 400ms sample blocks).

• EBU G8

• EBU G10

• ARIB TR-B32

• A85 1770-1

• A85 1770-2