European EMC for ITE

89/336/EEC EMC Directive

EN 55022:1998 A2:2003 Class A

EN55024:1998 A2:2003 includes IEC/EN61000-2,3,4,5,6,11

EN61000-3-2:2000 Class A (Harmonics)

EN61000-3-3:1995 A1:2001 (Flicker)

ETSI/EN 300 386:v1.3.3, 2005-04 (EMC Telecommunications)

International EMC for ITE

CISPR22:1998 with A1 and A2 (Emissions)

CISPR24:1998 (Immunity)

IEC/EN 61000-4-2 Electrostatic Discharge, 8 kV Contact, 15 kV Air,
Critieria A

IEC/EN 61000-4-3 Radiated Immunity, 10 V/m, Criteria A

IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A

IEC/EN 61000-4-5 Surge, 2 kV L-L, 4 kV L-G, Level 4, Criteria A

IEC/EN 61000-4-6 Conducted Immunity, 0.15–80 MHz, 10 V/m, mod. RMS,
Criteria A

IEC/EN 61000-4-8 Magnetic Susceptibility, Criteria A

IEC/EN 61000-4-11 Power Dips & Interruptions, >30%,25 periods, Criteria C

Country-specific

VCCI Class A (Japan Emissions)

ACMA, CISPR22:2006 or AS/NZS 3548 (Australia/New Zealand)

BSMI, CNS 13438:1997, Class A (-Taiwan)

ANATEL, EMC Resolution 237 (Brazil)

MIC Mark by RLL (South Korea)

Environmental Specifications

Environmental Standards

EN/ETSI 300 019-2-1 v2.1.2 (2000–09) - Class 1.2 Storage

EN/ETSI 300 019-2-2 v2.1.2 (1999–09) - Class 2.3 Public Transportation

EN/ETSI 300 019-2-3 v2.1.2 (2003–04) - Class 3.1e Stationary Use

EN/ETSI 300 753 (1997-10) - Acoustic Noise

Green Compliance Standards

RoHS 6 compliant

China RoHs compliant

WEEE compliant

Operating conditions

Operating temperature range: 0 C to +40 C (32º F to 104º F)

Operating humidity: 10 – 90% relative humidity

Operating altitude: 0 – 3000 meters (10,000 ft)

Operating shock*: 30 m/s

2

(3g), 11 ms

Operational random vibration*: 5 – 500 Hz @ 1.5G

rms

Acoustic noise: < 5.5 bels A sound power per ISO 7779

< 45.0 dBA declared sound pressure