Data routing, Automatic data routing, Manual data routing – Grass Valley NV9649 v.1.1 User Manual

Page 103: Semi-automatic data routing

Advertising
background image

91

NV9649

User’s Guide

Data Routing

There are 3 data routing options that affect sources and destinations that have a machine
control level (i.e., a data level). These options govern what happens when a source or destina-
tion device is to be used.

Automatic Data Routing

A take involving a machine control level occurs naturally on all selected levels, including the
machine control level, regardless of whether an affected machine control port is in use. The
system breaks any existing control connections involved with the source and destination and
makes a new control connection for the source and destination.
This data routing option applies in both operating modes.

Manual Data Routing

If a control port for the source or destination is “in use,” a take involving a machine control level
occurs on all levels except the machine control level. You must break either the source’s control
connection, the destination’s control connection, or both of those existing connections before
you can take the source to the destination on the machine control level. To break a connection,
route a device (as a source) to itself (as a destination) on the machine control level. When the
connection is broken, the status column of the display reads “FREE” for the machine control
level (in X-Y mode). If your panel is in multi-destination mode, you might switch to X-Y mode
momentarily to see this.
When a take involving a machine control level is blocked on the control level, the display
displays the message “Control In Use.”
If neither of the control ports for the source or destination are in use, the take occurs naturally
without any further action required. Note that the ports will become “in use” after the take you
are performing.

This data routing option applies in both operating modes.

Semi-Automatic Data Routing

This data routing option applies only in X-Y mode.

If a control port for the source or destination is “in use,” a take involving a machine control level
occurs on all levels except the machine control level. Nevertheless, you are given the opportu-
nity to complete the take on the machine control level by pressing the ‘Take’ button a second
time.
If neither of the control ports for the source or destination are in use, the take occurs naturally
without any further action required. Note that the ports will become “in use” after the take you
are performing.

Follow these steps to take the data level as a breakaway:

1 Select a destination.

2 Select a source.

3 Examine the display and the take button.

4 If the display shows “Control in Use” and the Take button is still high-tally, press the ‘Take’

button again to complete the take.

You can cancel the control-level take by pressing a button other than ‘Take’.