Analog diagnostics – HEIDENHAIN MSE 1000 User Manual
Page 137
Troubleshooting
Diagnostics
Operating Instructions
137
Analog diagnostics
Analog diagnostics are used to monitor the analog value from an analog device and
show the conversions to units, the effect of scaling, the effect of mastering, and the
electrical value used by the device.
Analog diagnostics:
Signal
Value
Value scaled
Value mastered
+5V 1
Ground
+5V 2
Vref
Analog diagnostics
Analog diagnostics
Signal
Displays the raw value in volts or mA.
Value
Displays the raw value multiplied by the calibrated resolution.
Value scaled
Displays the value multiplied by the scale factor.
Value mastered
Displays the scaled value with the master offset.
+5V 1
Displays the 5V source.
Ground
Displays the ground.
+5V 2
Displays a second readout of the 5V source.
Vref
Displays the reference voltage.