9 error messages, Display of errors, Open the error window – HEIDENHAIN TNC 320 (340 55x-03) User Manual

Page 111: Close the error window, 9 er ro r messag es 4.9 error messages

Advertising
background image

HEIDENHAIN TNC 320

111

4.9 Er

ro

r messag

es

4.9 Error messages

Display of errors

The TNC generates error messages when it detects problems such
as:

„

Incorrect data input

„

Logical errors in the program

„

Contour elements that are impossible to machine

„

Incorrect use of the touch probe system

When an error occurs, it is displayed in red type in the header. Long
and multi-line error messages are displayed in abbreviated form. If an
error occurs in the background mode, the word “Error” is displayed in
red type. Complete information on all pending errors is shown in the
error window.

If a rare “processor check error” should occur, the TNC automatically
opens the error window. You cannot remove such an error. Shut down
the system and restart the TNC.

The error message is displayed in the header until it is cleared or
replaced by a higher-priority error.

An error message that contains a program block number was caused
by an error in the indicated block or in the preceding block.

Open the error window

Press the ERR key. The TNC opens the error window

and displays all accumulated error messages.

Close the error window

Press the END soft key—or

Press the ERR key. The TNC closes the error window.

Advertising