Suppressing touch probe monitoring: m141, Delete basic rotation: m143 – HEIDENHAIN TNC 320 (340 55x-03) User Manual

Page 202

Advertising
background image

202

7 Programming: Miscellaneous Functions

7.

4 Miscellaneous F

unctions f

o

r Cont

our

ing Beha

vior

Suppressing touch probe monitoring: M141

Standard behavior

When the stylus is deflected, the TNC outputs an error message as
soon as you attempt to move a machine axis.

Behavior with M141

The TNC moves the machine axes even if the touch probe is
deflected. This function is required if you wish to write your own
measuring cycle in connection with measuring cycle 3 in order to
retract the stylus by means of a positioning block after it has been
deflected.

Effect

M141 is effective only in the block in which it is programmed.

M141 becomes effective at the start of the block.

Delete basic rotation: M143

Standard behavior

The basic rotation remains in effect until it is reset or is overwritten
with a new value.

Behavior with M143

The TNC erases a programmed basic rotation from the NC program.

Effect

M143 is effective only in the block in which it is programmed.

M143 becomes effective at the start of the block.

If you use M141, make sure that you retract the touch
probe in the correct direction.

M141 functions only for movements with straight-line
blocks.

The function M143 is not permitted during mid-program
startup.