Cycle parameters – HEIDENHAIN TNC 620 (81760x-01) Cycle programming User Manual

Page 367

Advertising
background image

DATUM IN ONE AXIS (Cycle 419, DIN/ISO: G419, software option

17)

15.13

15

TNC 620 | User's Manual Cycle Programming | 3/2014

367

Cycle parameters

1st meas. point 1st axis Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
1st meas. point 2nd axis Q264 (absolute):
Coordinate of the first touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Measuring axis (1...3: 1 = principal axis) Q272:
Axis in which the measurement is to be made:

1

: Principal axis = measuring axis

2

: Secondary axis = measuring axis

3

: Touch probe axis = measuring axis

Axis assignment

Active touch probe
axis: Q272= 3

Corresponding
reference axis:
Q272= 1

Corresponding
minor axis: Q272=
2

Z

X

Y

Y

Z

X

X

Y

Z

NC blocks

5 TCH PROBE 419 DATUM IN ONE AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q261=+25

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+50

;CLEARANCE HEIGHT

Q272=+1

;MEASURING AXIS

Q267=+1

;TRAVERSE DIRECTION

Q305=0

;NO. IN TABLE

Q333=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER