2 set policy port, Set policy port -24, Section 8.3.3.2 – Enterasys Networks 1G58x-09 User Manual

Page 416

Advertising
background image

Policy Classification Configuration Command Set

Assigning Ports to Policy Profiles

8-24

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

Example

This example shows how to display policy information for Fast Ethernet front panel port 21. In this
case, the port is allowed to transmit untagged frames to policy profile 1 based on the classification
rules assigned to that policy:

8.3.3.2

set policy port

Use this command to assign ports to a policy profile. Ports assigned will now be active for this
profile. Untagged frames received will be tagged according to the policy profile settings.

set policy port port-string admin-id

Syntax Description

Command Defaults

None.

Command Type

Switch command.

Command Mode

Read-Write.

Example

This example shows how to allow Fast Ethernet front panel ports 5 through 15 to classify frames
according to policy profile 5:

Matrix>show policy port fe.0.21

Port AdminId OperId

--------------------------

fe.0.21 1

1

port-string

Specifies the port(s) to add to the policy profile. For a
detailed description of possible port-string values, refer
to

Section 4.1.2

.

admin-id

Specifies the ID of the policy profile (role) to which the
port(s) will be added.

Matrix>set port policy fe.0.5-15 5