Show flowlimit output details – Enterasys Networks 1G58x-09 User Manual

Page 786

Advertising
background image

Security Configuration Command Set

Configuring Flow Setup Throttling (FST)

14-104

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

Example

This example shows how to display all flow limiting limits and actions:

Table 14-8

provides an explanation of the command output.

Matrix>show flowlimit limit

Flow limit status - enabled

Flow limit notifications - disabled

Flow limit shutdown - disabled

Flow limit notification interval - 120

Flow limit maximum flowcount - 128000

Flow limit table

----------------

Limit Action

---- -----

User port

limit 1 1

limit 2 0

Server port

limit 1 0

limit 2 0

Aggregation port

limit 1 0

limit 2 0

Interswitch link

limit 1 0

limit 2 0

Unspecified

limit 1 0

limit 2 0

Table 14-8

show flowlimit Output Details

Output

What It Displays...

Flow limit status

Whether FST is enabled or disabled. Default state of
disabled can be changed with the set flowlimit command
(

Section 14.3.9.2

).

Flow limit
notification

Whether flow limit notification (SNMP trap) is enabled or
disabled. Default state of disabled can be changed with the
set flowlimit notification command (

Section 14.3.9.7

).