A3 - 59 – Yaskawa PC NC User Manual

Page 299

Advertising
background image

A3 - 59

YASNAC PCNC Operating Manual

APPENDIX 3: Parameter Tables

pm2431

JOG feedrate corresponding switch
position 31

mm/min

0

32767

pm2432

Multiply of jog feedrate
parameter to 1, 10 or 100

times

0

100

pm2433

Specify JOG switch position
from which to multiply

0

31

When pm2432 not 0

pm2434

Specify JOG switch position
from which to

0

31

If pm2433 and pm2434
are specified simulta-
neously, pm2433 has
priority

pm2447

Feedrate of rapid feed override F0

mm/min

0

32767

1 =1 mm/min (If
pm2000 D3 = 0), 1 =
1%
If pm2000 D3 = 1

pm2448

Feedrate of rapid feed override F1

%

0

100

pm2449

Feedrate of rapid feed override F2

%

0

100

pm2459

x100 Multiplication of Handle feed

times

0

32767

pm4009

7

MST status when mode is changed
auto to manual
0: MST are finished and SPL off
1: MST are saved with SPL on

0

1

pm4015

0

Entry of program restart mode
0: By I/0
1: By soft-key

0

1

pm5000

0

Valid timing of cycle start signal
1: Valid when “0” (B contact0
0: Valid when “1” (A contact0

0

1

1

Validity of Internal toggle switch
0: Invalid
1: Valid

0

1

2

Turning ON of RST output signal
when ESP input signal is ON
0: Invalid
1: Valid

0

1

pm5001

0

Selection of external data input data
type
1: BCD
0: Binary

0

1

pm5400

Time from base block cancel to brake
release

msec

0

32767

pm5401

Time from ESP signal rising to base
block on

msec

0

32767

multiply of 10msec

pm5402

Time from ESP signal rising to base
block on 2nd axis

msec

0

32767

multiply of 10msec

pm5403

Time from ESP signal rising to base
block on 3rd axis

msec

0

32767

multiply of 10msec

Address

Bit

Description

Register

Units

Minimum

Value

Maximum

Value

Long Description

Advertising