Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 359

Advertising
background image

10.1 Alarm Displays

10-3

10

Trou

blesh

ooting

A.300

Regeneration Error

Regenerative circuit or regenerative resis-
tor is faulty.

Gr.1

Available

L

L

H

A.320

Regenerative Overload

Regenerative energy exceeds regenerative
resistor capacity.

Gr.2

Available

L

L

H

A.330

Main Circuit Power

Supply Wiring Error

• Setting of AC input/DC input is incor-

rect.

• Power supply wiring is incorrect.

Gr.1

Available

L

L

H

A.400

Overvoltage

Main circuit DC voltage is excessively

high.

Gr.1

Available

H

H

L

A.410

Undervoltage

Main circuit DC voltage is excessively
low.

Gr.2

Available

H

H

L

A.42A

Converter error

One of the following was detected by the
converter.

• An operation error occurred when using

the limit relay for inrush current

• PN voltage error
• Regeneration operation error
• The converter’s heat sink overheated
• An operation error occurred when using

the converter and fan

Gr.1

Available

H

H

L

A.450

Main-Circuit

Capacitor Overvoltage

The capacitor of the main circuit has dete-
riorated or is faulty.

Gr.1

N/A

H

H

L

A.510

Overspeed

The servomotor speed is above the maxi-
mum rotational speed.

Gr.1

Available

L

H

L

A.511

Overspeed of Encoder

Output Pulse Rate

The pulse output speed upper limit of the
set encoder output pulse (Pn212) is
exceeded.

Gr.1

Available

L

H

L

A.520

Vibration Alarm

Incorrect vibration at the motor speed was

detected.

Gr.1

Available

L

H

L

A.521

Autotuning Alarm

Vibration was detected while performing
tuning-less function.

Gr.1

Available

L

H

L

A.710

Overload: High Load

The servomotor was operating for several
seconds to several tens of seconds under a
torque largely exceeding ratings.

Gr.2

Available

L

L

L

A.720

Overload: Low Load

The servomotor was operating continu-
ously under a torque exceeding ratings.

Gr.1

Available

L

L

L

A.730
A.731

Dynamic Brake Overload

When the dynamic brake was applied,
rotational energy exceeded the capacity of
dynamic brake resistor.

Gr.1

Available

L

L

L

A.740

Overload of Surge

Current Limit Resistor

The main circuit power was frequently
turned ON and OFF.

Gr.1

Available

L

L

L

A.7A0

Heat Sink Overheated

The heat sink of the SERVOPACK or con-
verter exceeded 100

°C.

Gr.2

Available

L

L

L

A.7AB

Built-in Fan in

SERVOPACK Stopped

The fan inside the SERVOPACK stopped.

Gr.1

Available

L

L

L

A.810

Encoder Backup Error

The power supplies to the encoder all
failed and position data was lost.

Gr.1

N/A

H

H

H

A.820

Encoder Checksum Error

The checksum results of encoder memory
is incorrect.

Gr.1

N/A

H

H

H

A.830

Absolute Encoder Battery

Error

The battery voltage was lower than the
specified value after the control power
supply was turned ON.

Gr.1

Available

H

H

H

A.840

Encoder Data Error

Data in the encoder is incorrect.

Gr.1

N/A

H

H

H

A.850

Encoder Overspeed

The encoder was rotating at high speed
when the power was turned ON.

Gr.1

N/A

H

H

H

(cont’d)

Alarm

Number

Alarm Name

Meaning

Servomotor

Stopping

Method

Alarm

Reset

Alarm Code Output

ALO1 ALO2 ALO3

Advertising