Installation, 2 me-sbc, Wiring connections - solenoid drive – Magnum Energy Smart Battery Combiner (ME-SBC) User Manual

Page 10

Advertising
background image

7

©2009 Magnum Energy Inc.

Installation

2.4.2 ME-SBC

TM

Wiring Connections - Solenoid Drive

CAUTION: Before connecting any wires, turn off any battery charger

and loads that are connected to the

battery banks that the ME-SBC

TM

will be combining.

Info: If installing in a boat, RV or truck, ensure the conductors

passing through walls, bulkheads or other structural members are

protected to minimize insulation damage such as chafi ng; which can

be caused by vibration or constant rubbing.

The ME-SBC

TM

should now be mounted, if not please refer to section 2.2.

During installation please refer to Figures 2-6 during the following steps:
1. Unplug the Power Terminal Block from ME-SBC

TM

and ensure the open-

ings are unscrewed enough to allow the wires to be inserted.
2. Select and connect an appropriately sized red wire

1

from terminal #1 -

MAIN POS (+) on the Power Terminal Block to the positive terminal of

the Main Battery.
3. Select and connect an appropriately sized red with white stripe wire

1

from

terminal #2 - AUX POS (+) on the Power Terminal Block to the positive

terminal of the Auxiliary Battery.
4. Select and connect an appropriately sized black wire

1

from terminal #3

- COM NEG (-) on the Power Terminal Block to the negative busbar or

vehicle chassis.

Info: The negative busbar must connect the negative terminals on

the Main and Auxiliary Batteries together.

5. Use an appropriately sized wire

2

to connect each terminal of the solenoid

to the appropriate battery terminal. Please refer to Figure 2-4 for more

information

6. Connect one side of the solenoid coil to a positive post on the Main or Aux-

iliary Battery or one of the main terminal on the solenoid. Use the appropriate

fuse to protect the wire (2 Amp fast blow maximum). For more information,

please consult the solenoid manufacturers installation instructions.

7. Connect the other side of the solenoid coil to # 4 - SOLENOID (-) on the

Accessories Terminal Block.

8. When all the connections are made and checked, plug the Power Terminal

Block into the ME-SBC

TM

to supply DC power.

9. Immediately after applying DC power, the LED’s on the ME-SBC

TM

should

come on as the unit goes through a power-up self-test. After the initial self-

test completes, the Status LED should be Illuminated. If not, please refer to

the troubleshooting section.
note 1 : The wires connected to #1 - MAIN POS (+), #2 - AUX POS (+)

and #3 - COM NEG (-) should be sized for 30 amp. The battery positive

lines should be protected with a 30 Amp fast blow fuse. Wire size should be

appropriate for the application.

note 2 : The size of this wire will likely be determined by considering the

3% voltage drop requirements of the charging circuit. Always consult the

solenoid manufacturers installation documentation.

Advertising