Installation, 1 me-sbc, Wiring connections - 25 amp – Magnum Energy Smart Battery Combiner (ME-SBC) User Manual

Page 8: 24 v

Advertising
background image

5

©2009 Magnum Energy Inc.

Installation

2.4.1 ME-SBC

TM

Wiring Connections - 25 Amp

CAUTION: Before connecting any wires, turn off any battery charger

and loads that are connected to the

battery banks that the ME-SBC

TM

will be combining.

Info: If installing in a boat, RV or truck, ensure the conductors

passing through walls, bulkheads or other structural members are

protected to minimize insulation damage such as chafi ng; which can

be caused by vibration or constant rubbing.

The ME-SBC

TM

should now be mounted if not please refer to section 2.2.

During installation please refer to Figures 2-5 during the following steps:
1. Unplug the Power Terminal Block from ME-SBC

TM

and ensure the open-

ings are unscrewed enough to allow the wires to be inserted.
2. Select and connect an appropriately sized red wire

1

from terminal #1

- MAIN POS (+) on the Power Terminal Block to the positive terminal of

the Main Battery.
3. Select and Connect an appropriately sized red wire with a white stripe

1

from terminal #2 - AUX POS (+) on the Power Terminal Block to the positive

terminal of the Auxiliary Battery.

4. Select and connect an appropriately sized a black wire

1

from terminal #3

- COM NEG (-) on the Power Terminal Block to the Negative bus-bar or

vehicle chassis.

Info: The Negative busbar must connect the negative terminals on

the Main and Auxiliary Batteries together.

5. When all the connections are made and checked, plug the Power Terminal

Block into the ME-SBC

TM

to supply DC power.

Info: If there is a miswire in the system the “Reverse Polarity” LED

will be on. Correct the polarity of the wires connected to the Main

Terminal.

6. Immediately after applying DC power, the LED’s on the ME-SBC

TM

should

come on as the unit goes through a power-up self-test. After the initial self-

test completes, the Status LED should be illuminated. If so, your ME-SBC

TM

is now ready for set-up; if not, please refer to the troubleshooting section.

note 1 : The wires connected to #1 - MAIN POS (+), #2 - AUX POS (+)

and #3 - COM NEG (-) should be sized for 30 amps and the same size.

The battery positive #1 - MAIN POS (+) and #2 - AUX POS (+) lines

should be protected with a 30 Amp fast blow fuse. Wire size should be

appropriate for the application.

10 ft

15 ft

20 ft

30 ft

12 V

10 AWG

8 AWG

not recommended not recommended

24 V

12 AWG

12 AWG

10 AWG

8 AWG

Table 2-4, Recommended Wires Sizes for 3% loss

Advertising