Operation – Magnum Energy Smart Battery Combiner (ME-SBC) User Manual

Page 16

Advertising
background image

13

©2009 Magnum Energy Inc.

Operation

5.0 LED Indicators
The LEDs on the front of the ME-SBC

TM

are there to communicate the status

of the ME-SBC

TM

, Faults, and Warnings. Use the table below to determine the

status of the device.

The Reverse Polarity LED indicates that the wiring to the Main Terminal is

incorrect. Correct the reverse polarity and the LED should turn off.

ME-SBC

TM

STATUS and DISCONNECTED LED Indicators

Status LED

(bi-color Red or

Green)

Disconnected

LED (Yellow)

Description

OFF

OFF

No Power

OFF

ON

Low Voltage Disconnect (LVD).

Disconnected

OFF

Slow Blink

High Voltage Disconnect (HVD).

Disconnected

Solid Green

OFF

FET switch connects MAIN and AUX

connect voltage requirement is met

on either battery, connected

Slow

Blinking Green

OFF

FET Temp > 80C – goes to 50% duty

cycle for charging, connected

Slow Blinking

Red

ON

FET Temp > 90C, temperature

disconnect. Auto reconnect when

FET temperature falls below 70C

and if voltage meets “connect” spec.

Disconnected

Fast

Blink

Red

OFF

Average current > 20 Amp. Auto-

reconnect after 10 Secs if voltage

meets “connect” setting. Discon-

nected

Solid

Red

ON

Average current >30A, current

disconnect. Auto reconnect after

10secs when FET temperature falls

below 70C and if voltage meets “pull-

in” spec. Disconnected

Table 5-1, LED Indicators