Remote bulb control installation instructions – Empire Products GWT-35-2(SG User Manual

Page 17

Advertising
background image

12425-10-1008

Page 17

Index

Part

No.

Number

Description

1

GW-130

Remote Bulb Control Kit

2

R-1224

Remote Bulb Control

3

R-2499

Wire Assembly

4

R-1162

Control Knob

5

R-1720

Plastic Clip (3 Required)

6

R-1223

Instructions

7

R-1578

No. 6-32 x 1/4" (6mm) Screw (2 Required)

Caution: Remote bulb wire routing is important. Wires should be

in proper location to avoid damage from being overheated.

Incorrect routing of remote bulb control wires may result

in damage to wires and incorrect operation of remote bulb

control. Follow these instructions and refer to the drawing for

proper wire routing.

7. If remote bulb control is located on the right side of the outer casing,

carefully bend or loop capillary wire around control. This will enable

the sensing bulb to be positioned at the bottom of the unit.

8. Secure sensing bulb on the inside, at the bottom, of the outer casing

with (2) plastics clips.

9. Feed the wire assembly down along the inside of the outer casing.
10. Use third plastic clip to secure wire assembly and capillary wire to

the casing. (Approximately 24" (610mm) from bottom of unit.)

11. Attach control knob to remote bulb control.
12. Install furnace according to instructions in the Installation Instructions

and Owner's Manual.

Note: If wall furnace is already installed, secure outer casing to unit.
13. Attach wire assembly to gas valve at the "TH" and "TH/TP" terminals

on the Robertshaw valve.

Attach wire assembly to gas valve at the "THERMO" terminals on

the ITT valve. If the wire assembly has two 1/4" (6mm) female con-

nectors, the connectors should be cut off the wire assembly. Strip

and bare the wires and attach wires to the "THERMO" terminals.

Note: This remote bulb control is connected to the gas valve the same

way as a wall thermostat. Any references made to the thermostat in the
lighting instructions would also apply to the remote bulb control.

INSTRUCTIONS

Note: At the option of the owner, the remote bulb control may be located

on the left or right side of the outer casing.

1. Remove remote bulb control from the shipping carton.
2. Remove outer casing assembly from shipping carton.

Note: If wall furnace is already installed, remove outer casing from

unit and lay on floor with front side down.

3. Attach wire assembly to remote bulb control.
4. Carefully unwind capillary wire on remote bulb control.
5. Remove (3) hole plugs from left or right side of outer casing where

remote bulb control is to be installed.

6. Mount remote bulb control to inside of outer casing with (2) No. 6-32

x 1/4" (6mm) screws.

TO VENT SAFETY

TO REMOTE BULB

T

O

THER

MOPIL

E

MODELS

GWT-25 RB, GWT-35 RB, GWT-50 RB

REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS