Empire Products GWT-35-2(SG User Manual

Page 19

Advertising
background image

12425-10-1008

Page 19

Fan Control

The automatic fan control is located on the bottom of the blower assembly.

The fan control is a nonadjustable, automatic type. The fan control will

require between 3 and 7 minutes of main burner operation before the fan

control "closes" and activates the blower. The blower will continue to run

between 3 and 7 minutes after the main burner shuts off, before the fan

control "opens" and deactivates the blower.
Wiring

The appliance, when installed, must be electrically grounded in accordance

with local codes or, in the absence of local codes, with the National Electrical

Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an

external electrical source is utilized. This appliance is equipped with a

three-prong [grounding] plug for your protection against shock hazard

and should be plugged directly into a properly grounded three-prong

receptacle. Do not cut or remove the grounding prong from this plug.

For an ungrounded receptacle, an adapter, which has two prongs and a wire

for grounding, can be purchased, plugged into the ungrounded receptacle

and its wire connected to the receptacle mounting screws. With this wire

completing the ground, the appliance cord plug can be plugged into the

adapter and be electrically grounded.

WARNING:

Unplugging of blower accessory will not stop the heater from

cycling. To shut heater off: Turn temperature dial or thermostat

to lowest setting. Turn knob on gas control to "OFF", depressing

slightly. Do not force.

CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Oiling

The blower motor does not have oiling holes. Do not attempt to oil the

blower motor.

13”

(330 mm)

4 7/16”

(112.6 mm)

PARTS LIST

INDEX

PART

NO.

NUMBER

DESCRIPTION

1

R-2204

CORD SET

2

8720161

STRAIN RELIEF BUSHING

3

15888

BLOWER HOUSING ASSEMBLY

4

8520142

BRASS BUSHING (4 REQUIRED)

5

GWT-197

BLOWER SIDE (2 REQUIRED)

6

R-3085

WIRE ASSEMBLY

7

R-2503

FAN SWITCH

8

15887

BLOWER FRONT

9

8520141

RUBBER GROMMET (4 REQUIRED)

10

R-2804A

BLOWER MOTOR

Figure 3

GWTB-2 WIRING DIAGRAM

Advertising
This manual is related to the following products: