Mounting the RAC 104

The RAC 104 can be set on a table or mounted on a rack shelf,
under a desk or tabletop, or on a projector mount.

UL rack mounting guidelines

The following Underwriters Laboratories (UL) guidelines
pertain to the safe installation of the RAC 104 in a rack.

1.

Elevated operating ambient temperature

— If installed in

a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore,
install the RAC 104 in an environment compatible with the
maximum ambient temperature (Tma = +122 °F, +50 °C)
specified by Extron.

2.

Reduced air flow

— Install the equipment in a rack so that

the amount of air flow required for safe operation of the
equipment is not compromised.

3.

Mechanical loading

— Mount the equipment in the rack

so that a hazardous condition is not achieved due to
uneven mechanical loading.

4.

Circuit overloading

— Connect the equipment to the

supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this
concern.

5.

Reliable earthing (grounding)

— Maintain reliable

grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).