Caution – Extron Electronics RAC 104 User Manual

Page 19

Advertising
background image

RAC 104 • Installation and Operation

2-7

3

RS-232 connector

— Plug an optional RS-232 device into this

3-pole captive screw connector. Wire the connector as shown
below.

Transmit (Tx)

Receive (Rx)

Ground (Gnd, )

RS-232

Tx Rx

Pin

RS-232 function

Description

1

Tx

Transmit data

2

Rx

Receive data

3

Gnd

Signal ground

4

Line level selector DIP switches

— Set these switches to

-10 dBV (unbalanced, consumer line level) or +4 dBu (balanced,
professional line level). There are four switches, one for each
input group and output group.

ON

LINE LEVEL

IN

A B A B

OUT

+4 dBu

-10 dBV

5

Power connector

— An external 12 V power supply is included

with the unit. Plug it into this 2-pole captive screw connector.
Wire the connector as shown below.

Orange Captive Screw

Connector

Tie Wrap

Power Supply

Output Cord

Ridges

Smooth

A

A

SECTION A–A

CAUTION

When connecting the power supply, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the RAC 104. Identify the power
cord negative (ground) lead by the ridges on the
side of the cord or a black heat shrink wrapping
around it.

The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.

To verify the polarity before connection, check the no load
power supply output with a voltmeter.

Advertising