Adding a new switch to an existing stack – Enterasys Networks A2H124-24FX User Manual

Page 43

Advertising
background image

Configuring Switches in a Stack

SecureStack A2 Installation Guide 3-15

3.

Once the desired master switch has been selected, the current configuration will be 
saved and the stack will automatically reset. You must now move the console cable to 
the new management unit.

4.

Stack members other than the management unit will only identify their unit number 
through their console port.

5.

Persistent data on all stack units can be cleared along with the current configuration 
using the clear config all as described in the SecureStack A2 Configuration Guide.

Adding a New Switch to an Existing Stack

Use the following procedure to install a new switch to an existing stack configuration. 
This procedure assumes that the new switch being added has a clean configuration from 
manufacturing and is running the same firmware image version as other switches in the 
stack.

1.

Ensure that power is off on the new switch being installed.

2.

Use one of the following methods to complete the stack cable connections:

If the running stack uses a daisy chain topology, make the stack cable connections 
from the bottom of the stack to the new switch (that is, STACK DOWN port from 
the bottom switch of the running stack to the STACK UP port on the new switch).

If the running stack uses a closed loop configuration, break the loop and make the 
stack cable connections to the new switch to close the loop.

3.

Apply power to the new switch.

Important Considerations About Using Clear Config in a Stack

When using the clear config command (as described in the SecureStack A2 Configuration Guide)
to clear configuration parameters in a stack, it is important to remember the following:

• Use clear config to clear config parameters without clearing stack switch IDs. This command

WILL NOT clear stack parameters and avoids the process of re-numbering the stack.

• Use clear config all when it is necessary to clear all config parameters, including stack switch

IDs and switch priority values.

Considerations About Using Clear Config on a Standalone A2 with

the Uplink Ports Configured as Standard Gigabit Ethernet Ports.

When using the clear config command (as described in the SecureStack A2 Configuration Guide)
to clear configuration parameters on a standalone A2 switch with the uplink ports configured as
standard Ethernet ports (Ethernet mode), it is important to remember the following:

• The clear config command WILL NOT set the front panel uplink ports back to stack ports.
• The clear config all command WILL set the front panel uplink ports back to stack ports.

Advertising