Application notes – Enterasys Networks V2H124-24P User Manual

Page 34

Advertising
background image

Network Planning

2-6

2

Application Notes

1.

Full-duplex operation only applies to point-to-point access (such as when a
switch is attached to a workstation, server or another switch). When the switch
is connected to a hub, both devices must operate in half-duplex mode.

2.

Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals may
degrade overall performance for the segment attached to the hub.

3.

As a general rule the length of fiber optic cable for a single switched link should
not exceed:

• 1000BASE-SX: 550 m (1805 ft) using multimode fiber

• 1000BASE-LX: 5 km (3.2 miles) using single-mode fiber

• 100BASE-LH: 70 km (43.5 miles) using single-mode fiber

However, power budget constraints must also be considered when calculating
the maximum cable length for your specific environment.

Advertising