1000base-t pin assignments, 1000base-t pin assignments b-3, Table b-2 – Enterasys Networks V2H124-24P User Manual

Page 55: 1000base-t mdi and mdi-x port pinouts, Figure b-3, Crossover wiring

Advertising
background image

Twisted-Pair Cable and Pin Assignments

B-3

B

Figure B-3. Crossover Wiring

1000BASE-T Pin Assignments

All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.

The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.

Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length
of any twisted-pair connection does not exceed 100 meters (328 feet).

Table B-2. 1000BASE-T MDI and MDI-X Port Pinouts

1000BASE-T MDI and MDI-X Port Pinouts

Pin

MDI-X Signal Name

MDI Signal Name

1

Bi-directional Data Two Plus (BI_D2+)

Bi-directional Data One Plus (BI_D1+)

2

Bi-directional Data Two Minus (BI_D2-)

Bi-directional Data One Minus (BI_D1-)

3

Bi-directional Data One Plus (BI_D1+)

Bi-directional Data Two Plus (BI_D2+)

4

Bi-directional Data Four Plus (BI_D4+)

Bi-directional Data Three Plus (BI_D3+)

5

Bi-directional Data Four Minus (BI_D4-)

Bi-directional Data Three Minus (BI_D3-)

6

Bi-directional Data One Minus (BI_D1-)

Bi-directional Data Two Minus (BI_D2-)

7

Bi-directional Data One Plus (BI_D3+)

Bi-directional Data One Plus (BI_D4+)

8

Bi-directional Data Three Minus (BI_D3-)

Bi-directional Data Four Minus (BI_D4-)

White/Orange Stripe

Orange

White/Green Stripe

Green

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

End A

End B

White/Brown Stripe

Brown Stripe

Blue

White/Blue Stripe