100 mbps fast ethernet collision domain, 10 mbps ethernet collision domain, Cable labeling and connection records – Enterasys Networks V2H124-24P User Manual

Page 50: Cable labeling and connection records 4-6, Table 4-4, Maximum 1000base-lh gigabit ethernet cable length, Table 4-5, Maximum fast ethernet cable lengths, Table 4-6, Maximum ethernet cable length

Advertising
background image

Making Network Connections

4-6

4

Table 4-4. Maximum 1000BASE-LH Gigabit Ethernet Cable Length

100 Mbps Fast Ethernet Collision Domain

Table 4-5. Maximum Fast Ethernet Cable Lengths

10 Mbps Ethernet Collision Domain

Table 4-6. Maximum Ethernet Cable Length

Cable Labeling and Connection Records

When planning a network installation, it is essential to label the opposing ends of
cables and to record where each cable is connected. Doing so will enable you to
easily locate inter-connected devices, isolate faults and change your topology
without need for unnecessary time consumption.

To best manage the physical implementations of your network, follow these
guidelines:

• Clearly label the opposing ends of each cable.
• Using your building’s floor plans, draw a map of the location of all

network-connected equipment. For each piece of equipment, identify the devices
to which it is connected.

• Note the length of each cable and the maximum cable length supported by the

switch ports.

• For ease of understanding, use a location-based key when assigning prefixes to

your cable labeling.

• Use sequential numbers for cables that originate from the same equipment.
• Differentiate between racks by naming accordingly.
• Label each separate piece of equipment.
• Display a copy of your equipment map, including keys to all abbreviations at each

equipment rack.

Fiber Size

Fiber Bandwidth

Maximum Cable Length

Connector

9/125 micron

single-mode fiber

N/A

2 m - 70 km (7 ft - 43.5 miles) LC

Type

Cable Type

Max. Cable Length

Connector

100BASE-TX Category 5 or better 100-ohm UTP or STP 100 m (328 ft)

RJ-45

Cable Type

Maximum Length

Connector

Twisted Pair, Category 3 or better 100-ohm UTP

100 m (328 ft)

RJ-45

Advertising