Here are two connection options:

Option 1
This shows independent 12 VDC outputs that will turn on any compatible external amplifier with
a 12 VDC trigger input. Use the middle relay contacts to enable another independent device that
will turn on (as the contacts close) whenever a “trigger enabled” input in the MAIN ZONE has been
selected. DO NOT use the center relay contacts for 120 VAC or 240 VAC switching! They are only for
low voltage AC/DC loads of 2 A maximum. Typically this will mean low voltage control of structured
lighting systems, automated window coverings, or other low voltage devices. Never switch anything
that plugs directly into the wall with these on-board contacts. This action will damage the
unit and VOID THE WARRANTY.

Option 2
This simply shows looping the 12 VDC into the relay contact to turn on a device using the available
12 VDC trigger already supplied.

Use either output to activate

the MAIN ZONE amplifier(s)

See Option 1