SAG581126000

System Application Guide

Issue AD, November 23, 2009

Spec. No. 581126000 (Model 700

NVBA

)

Page 106 of 123

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

SYSTEM LOAD MENU

86

SYSLOAD** #####A

87

MEASUREMENT MENU

88

NORMAL DISPLAY

PCU LOAD MENU

89

PCU** LOAD #####A

90

MEASUREMENT MENU

91

NORMAL DISPLAY

SUBSYSTEM LOAD MENU

92

SUBLOAD** #####A

93

MEASUREMENT MENU

94

NORMAL DISPLAY

BATTERY LOAD MENU

94A

94B

BAT** CHG #####A
BAT** DIS #####A

94C

MEASUREMENT MENU

NORMAL DISPLAY

SYSTEM ADJUSTMENT MENU

95

FLOAT = ###.##V

96

TEST/EQ = ###.##V

97

SET HVS = ###.##V

99

CURR LIM = ####A

CURRLIM = #####MAX

99A

BATTLIM DISABLED
BATTLIM = #####A

100

100% CURR: ####A

101

ADJUSTMENT MENU

102

NORMAL DISPLAY

ALARM ADJUSTMENT MENU

FUNCTION MENU

MEASUREMENT MENU

41

MEASUREMENT MENU

42

SET TEST/EQ MODE
SET FLOAT MODE

TestEq Switch On

43

ADJUSTMENT MENU

44

CONFIGURE MENU

45

CALIBRATION MENU

46

NORMAL DISPLAY

ADJUSTMENT MENU

LVD ADJUSTMENT MENU

68

ADJUST SYSTEM

69

ADJUST ALARMS

70

ADJUST LVDs

71

FUNCTION MENU

72

NORMAL DISPLAY

CONFIGURE MENU

114

LVD ** = ##.#V

115

LV RECON = ##.#V
MANUAL RECONNECT

116

ADJUSTMENT MENU

117

NORMAL DISPLAY

INVENTORY MENU

CALIBRATION MENU

PCU ENABLE MENU

130

PCU** ON:SET OFF
PCU** OFF:SET ON
Energy Mgmt. On

131

CONFIGURE MENU

132

NORMAL DISPLAY

118

PCU** TYPE ####A

NO PCUs FOUND

PCU** TYPE ####+

119

VACANT ****A= ##
****A PLACES= ##

120

SHUNT** TYPE SYS
SHUNT** TYPE SUB

SHUNT** TYPE BAT
NO SHUNTS FOUND

121

LVD** INSTALLED
NO LVDs FOUND

121A

122

SUBSYS INSTALLED
NO SUBSYS FOUND

123

REMOTE INSTALLED

REMOTE ACTIVE
NO REMOTE FOUND

124

UPDATE INVENTORY
PLEASE WAIT...
REPLACE ** PCUs?

125

CONFIGURE MENU

126

NORMAL DISPLAY

127

SPEC NO. #########

128

MCA SWV ########

129

REM SWV ########

ANALOG TC FOUND

NO TEMP SENSORS

T SENSOR** INST

103

104

105

106

SYS 50% = ###.##V
VERYLOVOLT = ###.##

14

107

SYSCURR = #####A

108

SUB HV = ###.##V

109

SUB LV = ###.##V

110

SUBCURR = #####A

110A

BAT CHG = #####A

111

112

ADJUSTMENT MENU

113

NORMAL DISPLAY

HI TEMP** = ###°C
HI TEMP** IS OFF

LO TEMP** = ###°C

LO TEMP** IS OFF

61

SYSTEM ###.##VDC

62

SYS LOAD #####A

63

PCU LOAD #####A

64

SUBSYS ###.##VDC

65

SUB LOAD #####A

65A

BAT CHG #####A
BAT CHGCL #####A
BAT DIS #####A

66

FUNCTION MENU

67

NORMAL DISPLAY

65B

T SENSOR** ###°C

73

VERIFY INVENTORY

73C

DISPLAY ROLL OFF
DISPLAY ROLL ON

74

SET PCU ON / OFF

74A

LO SPEED FAN OFF
LO SPEED FAN ON

75

NAG MINUTES = ##
AUDIBLE NAG OFF

76

TEST/EQ HRS = ##
TEST/EQ MAN STOP
END TEQ ##.##HRS

76A

AUTO EQ DISABLED
AUTO EQ MUL = ##
END AUTO ##.## HR

77

RELAYTEST = ###SEC

78

FUNCTION MENU

79

NORMAL DISPLAY

80

CAL SYS = ###.##V

81

CAL SUB = ###.##V

82

RESTORE MFG CAL

83

ANALOG TC OFF
TC CAL = ##.##V
TempCmp Hardware

84

FUNCTION MENU

85

NORMAL DISPLAY

DIGITAL TC OFF
SLOPE = .###V/°C
TempCmp Hardware

MAX W/T = ##.##V

MIN W/T = ##.##V

N

ET

S

URE™

MCA Menu Tree

(Sheet 2 of 2)

A

from Sheet 1

110B

110C

83A

83B

83C

77A

SET SPANISH TEXT

TEST RELAYS
TESTING RELAY #
Alarm(s) Active

SYS HV1 = ###.##V
HI FLOAT = ###.##V

15

SYS HV2 = ###.##V

HI VOLTAGE = ###.##V

15

SYS BOD = ###.##V
LO FLOAT = ###.##V

15

LO VOLTAGE = ###.##V

15

73A

SHARE ALARM OFF
SHARE ALARM ON

83D

TCOMP ON SENSOR1
TCOMP ON AVERAGE
TCOMP ON HIGHEST

EMERG STOP OFF
EMERG STOP ON

REMOTE HVS OFF
REMOTE HVS ON

73B

73D