3-4 Chapter 3

Cabling Connections

Cabling specifications for each adapter type (DCP286i-SBC, DCP386i and
DCP486e) are found in the following section. Cabling differences will be
noticed when connecting a DTE port to a DCE device (normally a straight
through cable), and when connecting a DTE port to a DTE device (normally
a null modem cable). Factory setting on all cabling is DTE.

Factory Default Settings

DCP286i-SBC Adapter Cables

The DCP286i-SBC adapter is shipped with two standard adapter cables
which convert the Micro-D25 male output to a standard DB25 output. Install
the adapter cable for the environment in which you are working:

− RS232, Emulex part no. PT1011208-01
− V.35, Emulex part no. PT1011213-01

DCP386i/486e Daughterboard Cabling

This section discusses the default cable connections between the 8-port
daughterboard on the DCP386i and DCP486e adapters and external devices.

RS-232 Cabling

The serial ports on the 8-port daughterboard are connected to external
devices via an 8-port breakout cable, also known as an Octopus cable. Each
output provides a standard 25-pin male RS-232C connector for attachment to
external devices.

NOTE: All connections to the board should be made using

shielded cables to reduce radio frequency
interference.