6 physical installation – EAW DSA250i User Manual

Page 10

Advertising
background image

3.6

Physical Installation

3.6.1

ORIENTATION

1. When installing the enclosure, there is a correct “top”

and “bottom”. This cannot be assumed from the
physical appearance. Instead, orientation depends on
application and desired acoustical performance
determined using DSAPilot.

2. Ensure the enclosure is oriented correctly by

verifying which ends are supposed to be the top and
bottom for the intended application. The Signal End
is the end with the identification LED, visible on
one end of the front of the enclosure. The Power
End has the ac mains connector.

NOTE: The desired coverage cannot be achieved if the
enclosure is incorrectly oriented.

3.6.2

MOUNTING

WARNING: Comply with all installation warnings in Section 5.6.1.

The DSAi Series modules are normally intended to be flush-mounted
against a vertical surface capable of supporting their weight.

1. Using the template printed on the shipping box, locate and position

the supplied Wall Brackets to structure.

2. Attach the Wall Brackets to structure. You must provide attachment

hardware and ensure the attachment method and structure are capable
of supporting the intended load. Position the Wall Bracket weld nuts
left or right to allow clearance for later insertion of the Retainer Bolt.

3. Ensuring they are oriented properly, install the two Enclosure

Brackets on the module. Insert and hand-tighten the supplied 3/8-16
Enclosure Bracket Bolt and Lock Washer for each Enclosure
Bracket.

4. Lift the enclosure onto the installed Wall Brackets.

WARNING: Use at least two people for lifting enclosure onto the
brackets.

5. Insert and snugly tighten at least one of the supplied 1/4-20 Retainer

Bolt and Lock Washer through the side of either of the Wall and
Enclosure Brackets. This prevents the enclosure from being lifted off
the Wall Brackets.

6. Securely tighten each 3/8-16 Enclosure Bracket Bolt to lock the

enclosure at the desired horizontal angle.

6

1/4-20 X 3 LG

HEX HEAD

RETAINER BOLT

& LOCK WASHER

2X 3/8-16 X 2 LG

BLACK HEX HEAD

ENCLOSURE BRACKET

BOLT & LOCK WASHER

2X ENCLOSURE

BRACKET P/N 0006118

2X WALL BRACKET

P/N 0006119

Figure 3.6.2a Bracket Installation

Figure 3.6.2b Installed Bracket

LED INDICATOR

ON FRONT SURFACE

POWER END

SIGNAL END

AC MAINS CONNECTOR

Figure 3.6 Signal End / Power End

Advertising