2. Up to 2 ft / 0.6 m between adjacent side-by-side modules in a

cluster
User-supplied Cat-5 crossover cable.
Connect between unused Signal Link jacks (Neutrik EtherCon) on
horizontally adjacent ends of the modules.

5.1.5

DAISY CHAINING COMPUTER AND AUDIO SIGNALS BETWEEN
CLUSTERS

Any distance (within EIA-485 limitations) between clusters:
2-conductor shielded cable
Audio A, Audio B, and EIA-485

Connect in parallel to the incoming signal cables on one module

in the first cluster and connect to the same signal ports on one
module in the next cluster. Use the supplied 3-pin Phoenix
Contact terminal plugs.

Recommended Conductor Gauge:
24 AWG to 18 AWG / 0.2 mm to 1 mm

5.1.6

EIA-485 TERMINATE SWITCH

EIA-485 termination has special requirements and limitations. See

Appendix 8.3 for details.

Single Cluster:

Set the EIA-485 Terminate Switch on the module (connected via
the Phoenix connector) to “ON”.

Multiple Clusters:

Set the EIA-485 Terminate Switch to “ON” ONLY on the
module (connected via the Phoenix connector) at the end of
the EIA-485 cable run furthest from the computer. Set all
other Terminate Switches to “OFF”.

CAUTION: Engaging the EIA-485 Terminate Switch on more

than one module on the EIA-485 cable run can cause intermittent
or nonexistent communications.

15

Crossover Cable Wiring

STANDARD END PINS

1 2 3 4 5 6 7 8

CROSSOVER END PINS 3 6 1 4 5 2 7 8

EIA-485

AUDIO A

AUDIO B

Figure 5.1.5 Linking > 2 ft / 0.6 m

EIA-485 TERMINATE SWITCH

EIA-485

TERMINA

TE

AU

DIO

GR

OUND

LIFT

ON

OFF

LIFT

Figure 5.1.6a EIA-485 Terminate Switch

RS-232

OR USB

TO EIA-485

CONVERTER

PC

DSA
CLUSTERS

TERMINATE
SWITCH "OFF"

TERMINATE
SWITCH "OFF"

TERMINATE
SWITCH "ON"

Figure 5.1.6b EIA-485 Network Diagram