5 grounding – EAW DSA250i User Manual

Page 25

Advertising
background image

If it is desired to completely power off (de-energize) the module, a
conveniently located ac mains disconnect must be supplied or the power
cable must be unplugged from the module or the ac mains supply.

The PowerCon connector is a locking connecter. To lock, twist 1/4 turn
clockwise after fully inserting into the jack. It is recommended the
connection be made at the module before connection to the ac mains supply.

5.4.4

AC MAINS FUSE

If excessive ac mains input current is detected, an internal fuse can blow.
This can occur for a variety of reasons, such as internal failure,
excessive ac mains voltage, or excessive amplifier output levels.

If the fuse blows, the fuse must be replaced with a fuse of the correct
type and rating as listed below. In the unlikely event the fuse blows
again, internal failure is indicated. This will require troubleshooting and
repair by a qualified service technician. Do not attempt further use of the
module until such repairs are made. See Section 8.2 “Troubleshooting”.

Fuse Type:

AG (0.25 in x 1.25 in) slow-blow

Amperage

4 A

5.5

Grounding

5.5.1

ELECTRICAL GROUND

Ensure that the ac mains grounding conductor in the power cable is
properly grounded in accordance with applicable electrical codes.

5.5.2

AUDIO GROUND

The Audio Ground Lift switch may help isolate audio ground loops.
This dip switch disconnects the internal audio ground from the chassis.
Use this switch as needed for reducing ground loop noise.

21

POWER END

CAP

FUSE

HOUSING

Figure 5.4.4 Fuse

SIGNAL END

EIA-485

TERMINA

TE

AU

DIO

GR

OUND

LIFT

ON

OFF

LIFT

GROUND

LIFT

SWITCH

LIFT

PHOENIX

CONNECTORS

AUDIO A

AUDIO B

2X

AUDIO

SHIELD

PINS

EMI

FILTER

EMI

FILTER

CHASSIS/MAINS

GROUND

AUDIO

GROUND

AUDIO

GROUND

LIFT

SWITCH

Figure 5.5.2a Ground Lift Switch

Figure 5.5.2b Ground Lift Function