34

8.2

Troubleshooting

This troubleshooting table addresses some common faults. For other difficulties not listed, contact the EAW
Service Department.

SYMPTOM

POSSIBLE CAUSE

SOLUTION

DSA250i Only:
No HF output

Failed internal component

Module needs service.

No HF output from

Failed internal component

Module needs service.

one or more drivers

DSA250i and DSA230i:
Modules connected within a

Supplied Link Cable

Check link cable for proper operation

cluster by the Signal Link

is faulty

and ensure the RJ-45 connectors are

jacks do not function

fully engaged when inserted.

Modules connected within

User-supplied link

Ensure link cable is wired as a

a cluster by the Signal Link

cable is incorrect

standard Ethernet crossover cable

jacks do not function

and is less than 2 ft / 0.6 m long

No LF output

Failed internal component

Module needs service.

No LF output from one

Failed internal component

Module needs service.

or more drivers

No output

Incorrect connections

Check that input cabling to the
module is wired correctly for the
+/- signal wires and cable shield.

No output

Module is off

Check that power is supplied to the
module power cable and that the
cable is connected to the module.

No output

Module is off

Check the fuse on the power
end of the module. Replace if
blown. If the fuse blows again,
the module requires service.

No output

Amplifier is off

Using DSAPilot, check that
the power management functions
are set correctly.

No output

No input signal

Using DSAPilot monitoring
function, check that there is signal
at the input. If not, disconnect
and check for signal on the audio
input cable to the module.

No or low output

Input level is not set correctly Using DSAPilot, check that the

gains for the input(s) being used are
set properly.