EAW DSA250i User Manual

Page 9

Advertising
background image

3.3

Computer Control Connection

NOTE: Set the EIA-485 Terminate Switch to “ON”. For multiple
modules, see Chapter 5.

EIA-485:

2-conductor shielded audio cable/supplied
Phoenix Contact terminal block plug

3.4

Daisy Chaining Audio and Computer Signal
Between Modules

Distances up to 2 ft / 0.6 m are for connecting multiple modules in a
single cluster while distances over 2 ft / 0.6 m are for connecting
physically distributed clusters.

Up to 1 ft / 0.3 m: Supplied Cat-5 Signal Link Cable
Connect between Signal Link jacks (Neutrik® EtherCon®) on vertically
adjacent modules within a multi-module cluster.

Up to 2 ft / 0.6 m: User-supplied, Cat-5 Ethernet crossover cable
Connect between Signal Link jacks (Neutrik® EtherCon®) on
horizontally adjacent modules within a multi-module cluster.

Over 2 ft / 0.6 m: 2-conductor shielded audio cable / supplied Phoenix
Contact terminal block plugs

Connect Audio A, Audio B (if used), and EIA-485 in parallel daisy-chain
fashion between clusters.

3.5

AC Mains Installation

3.5.1

AC MAINS SUPPLY

Provide the module with a 50 Hz or 60 Hz ac mains circuit
capable of:

100 V to 120 V

220 V to 240 V

DSA230i and DSA250i

4 A

4 A

Before applying power, ensure that the ac mains voltage matches the
voltage rating on the module.

DANGER: DO NOT APPLY 230 V MAINS POWER IF THE VOLTAGE RAT-
ING ON THE MODULE IS 115 V. IMMEDIATE AND CATASTROPHIC
DAMAGE TO THE MODULE WILL RESULT AND MAY CAUSE A FIRE
HAZARD, SERIOUS PERSONAL INJURY, OR DEATH.

3.5.2

AC MAINS CABLE

Supply and connect #14 AWG / 2.5 mm power cable and appropriate ac
mains plug to the supplied Neutrik/PowerCon® connector.

5

EIA-485 DATA A

SHIELD

EIA-485 DATA B

Figure 3.3 EIA-485 Connector

LINK
CABLE
P/N
0005854

Figure 3.4a Signal Links < 1 ft / 0.3 m

EIA-485

AUDIO A

AUDIO B

Figure 3.4b Signal Links >2 ft / 0.6 m

Figure 3.5 Connecting AC Mains

Advertising
This manual is related to the following products: