5 proper dsai installations, Figure 8.6.5a example 1, Figure 8.6.5b example 2 – EAW DSA250i User Manual

Page 44

Advertising
background image

8.6.5

PROPER DSAI INSTALLATIONS

Here are some examples of DSAi installations that will work reliably, both avoiding loops and keeping EIA-
485 running well. These can be used as a basis for larger and more complex installations.

EXAMPLE 1:
This is a simple EIA-485 network
connected directly from the PC, which runs
DSAPilot, to DSAi "A" and then daisy-
chain fashion to "C". Because they are in
close physical proximity, Link cables are
used to connect the control data and audio
to "B" and "D". The termination switch for
"C" is on. The termination switch should be
off on all the other modules.

EXAMPLE 2:
This is a standard CobraNet connection.
Just like computers connected using
Ethernet, each module, whether used singly
or in a cluster, requires its own a connection
to a network switch. No Link cables are
used. The DSAPilot PC communicates to all
DSAi modules through the serial bridge in
the CobraNet Unit.

40

PC

DSA
PILOT

DSA "A"

CM1

SLink

485

PLink

CM1

SLink

485

PLink

DSA "C"

DSA "B"

CM1

SLink

485

PLink

DSA "D"

CM1

SLink

485

PLink

Figure 8.6.5a Example 1

Cobranet

Unit

Ethernet

Switch

PC

DSA

PILOT

DSA "A"

CM1

SLink

485

PLink

DSA "B"

CM1

SLink

485

PLink

DSA "C"

CM1

SLink

485

PLink

DSA "D"

CM1

SLink

485

PLink

Figure 8.6.5b Example 2