Flue – MCZ Forma Wood 75 Dx - mod.2012 User Manual

Page 13

Advertising
background image

1

9

9

2

3

4

5

6

7

8

11

4-FLUE

Technical Dept. - All rights reserved - Reproduction is prohibited

MAINTENANCE

The flue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draft, thus compromising

the efficient operation of the product and, if large build-ups accumulate, they can catch fire. The flue and chimney must be cleaned and

checked by a qualified chimney sweep at least once a year. Once the maintenance has been performed, request a written declaration that

the device is safe.

Failure to clean the system jeopardises the safety.

CHIMNEY

The chimney is a crucial element for the heating appliance to work properly: we recommend a wind proof chimney (A), see Figure 7.

The area of the opening for smoke

extraction must be at least double the

cross-section of the smoke duct/flue

system, and arranged so that smoke

extraction is ensured even in strong

wind. The chimney must prevent rain,

snow or animals from entering the

chimney. The height of outflow into

the atmosphere must be beyond the

reflux zone created by the shape of the

roof or any obstacles near the outlet

(see Figures 2-3-4-5-6).

CHIMNEY COMPONENTS

KEY:

(1) CHIMNEY

(2) REFLUX CHANNEL

(3) SMOKE DUCT

(4) THERMAL INSULATION

(5) OUTSIDE WALL

(6) CHIMNEY CONNECTION

(7) SMOKE CHANNEL

(8) HEAT GENERATOR

(9) INSPECTION ACCESS PANEL

FIGURE 7

FIGURE 8