Flue – MCZ Forma Wood 75 Dx - mod.2012 User Manual

Page 16

Advertising
background image

14

4-FLUE

TYPE OF DEVICE

SMOKE DUCT

Minimum vertical length

1.5 metres

Maximum length

(with 1 accessible 90° bend)

4.5 metres

Maximum length

(with 3 accessible 90° bends)

2.5 metres

Maximum number of accessible 90° bends

3

Horizontal sections

(minimum incline 3%)

2 metres

Use smoke ducts that are able to withstand the unit operating temperatures (min. T400). The use of flexible metal tubes in fibre

cement or aluminium is prohibited. For direction changes, we always recommend the use of a T joint with an inspection cap

allowing easy access for cleaning the tubes. Always ensure that the inspection cap is replaced and hermetically sealed with the seal in

tact after cleaning.

It is prohibited to connect more than one appliance to the same smoke duct, or the discharge from overhead cowling. It is prohibited to

extract the products of combustion directly through the wall, whether into indoor spaces or outdoors.

The smoke duct must be installed observing the safety distances from flammable materials as specified on the data plate (e.g. G400=

400 mm).