RISCO Group SMPS 3A User Manual

Page 11

Advertising
background image

SMPS - Installation Guide

11

DIP Switches Settings

Module

Dip Switch

Description

PS/SW1-
SW3

Used to set a unique ID number for the Bus
module for communication purposes.

Power
Supply

PS/SW4

Enables/Disables Power Supply - ProSYS
communication
On (up): Communication enabled.
Off (down): Communication disabled

UO/ SW1-
SW3

Used to set a unique Bus ID number for the UO
module located on the SMPS board.

Utility
output

UO/SW4

Enables/disables UO module - ProSYS
communication.
On (up): communication enabled.
Off (down): communication disabled

NOTE:

When PS/SW4, or UO/SW4 is Off, the ID number defined by SW1-SW3 is not
recognized by the ProSYS and can be used for the connection of another accessory
of the same category. The UO/PS LED will flash since there is no communication with
the main panel.

Jumper Settings

Jumper

Description
Battery discharge protection

Protection
ON

If a continuous AC power outage occurs, the
SMPS automatically disconnects the battery when
its backup battery voltage drops below 10.8VDC.
This is done to prevent "deep discharge” that may
damage the battery.

Protection
OFF

The battery may be totally discharged during
continuous AC failure (no deep discharge
protection).

BAT

NOTE:

If 2 pins configuration is selected, the battery might be damaged,
thus battery replacement may be required.