16

SMPS - Installation Guide

Trouble

Probable
Meaning /
Cause

Response

System
does not
function

PS/UO
Dipswitch ID
has been
changed

Reset the SMPS (see User

Programming Menu

on page 13),

disconnect battery and mains wires, wait
for few seconds, and reconnect the battery
and mains wires.

UO Relays
do not
operate
correctly

Incorrect UO
programming

Using the ProSYS menu, verify that the
UO functions are appropriately
programmed

Bus Test
less than
98%

Communication
with PS or UO
is not stable

The distance between ProSYS and SMPS
is too long; verify appropriate distance and
gauge of wiring (refer to Table 1: Wire
Gauge).

Post Installation Tests

Upon installation completion, verify that the SMPS is functioning by
conducting the “Verify Modules” and Bus Communication tests, from the
ProSYS menu.

Technical

Specifications

General

Ê

Efficiency: 93% @ 1A load, 85 % Min @ 3A full load

Ê

SMPS card dimensions (HxWxD): 90mm x110mm

Ê

Weight: 0.14Kg

Ê

Main Panel Connection: RS485, 3 Wire Bus, up to 300m from Main panel.

Input

Ê

Power: 16.5VAC @ 50VA (via 230VAC/16.5VAC/50Hz transformer).

Ê

Rechargeable Standby Battery: 12V Up To 21 Amp-Hours (AH)

Output

Ê

Auxiliary output: 3A @13VDC

Ê

Bell/Siren output: 1.7A @13VDC

Ê

Overload Protection: Automatic Electronic Protection

Utility Output

Ê

12VDC @ 3A max Dry Contact Relays

Environmental

Ê

Operating temperature: 0

q-55qC