Troubleshooting, Video, Usb-hid – Rose Electronics CrystalView DVI Mini User Manual

Page 23

Advertising
background image

TROUBLESHOOTING

CrystalView DVI Mini Installation and Operations Manual

19

Troubleshooting

Video

Diagnosis

Possible Reason

Possible Solution

Power LED off

Power supply

Check power supply units and
the connection to the mains.

Link Status
LED off

Connection between
Transmitter and Receiver
unit

Check the CATx cable and
connections

Video OK LED off

(Transmitter)

No video signal detected
From the source

Check DVI-D cable to CPU.
Download DDC information from
monitor
Reboot CPU if necessary

Video OK LED off

(Receiver)

No monitor detected

Check connection, length and
quality of the DVI-D cable to
monitor, tighten cable
thumbscrews

No video signal detected
from CPU Unit

Check connection, length and
quality of interconnect cable
between the units.
Download DDC information from
monitors.
Reboot CPU if necessary

Suboptimal transmission
parameters

Execute Auto-Adjust
manually adjust monitor
resolution

USB-HID

USB Status
LED off
(Transmitter)

No USB connection to the
computer

Check connection of USB cable
to CPU, select another USB port
if necessary.
Remove USB and power cable
and restart CPU. Connect power
cable first.

USB Status
LED off
(Receiver)

Check USB connection

Check connection of USB cable to
USB-HID device.
Remove DVI and power cable and
restart CON Unit. Connect power
cable first.

USB device does
not function

USB-HID device is not
supported

Contact tech support if necessary.

Advertising