CRYSTALVIEW DVI QUAD INSTALLATION AND OPERATIONS MANUAL

28

Next Frame Switching (Receiver unit)

The moment of switching to the next frame is set for switch during HSYNC (Default setting). This can be

modified to switch during VSYNC by removing the jumper JP3 as shown in Figure 9 and Table 4.

To modify the next frame switching, first remove power from the Receiver unit. Next, remove the screws on

the bottom and sides of the Receiver chassis and carefully remove the top of the chassis exposing the circuit

boards. Locate the jumper JP3 as shown in figure 9. Set jumper JP3 as shown in Table 3.


JP3

Figure 9. Jumper Settings (Receiver unit)

Moment to switch

JP3

Switching during HSYNC (Default)

Switching during VSYNC

Table 4. Moment of switching jumper (Receiver unit)

Switching during HSYNC will have a higher frame rate but horizontal screen breaks may be detectable.

Switching during VSYNC has a lower frame rate with no horizontal screen breaks but stepping pictures are

possible.