Auto reset (sensor) valve pe, Auto reset (sensor) valve performance check, Maintenance – SAF-HOLLAND XL-AR363-02 EDL/ARF Feature User Manual

Page 10: Auto reset (sensor) valve

Advertising
background image

XL-AR363-02 Rev. D

10

MAINTENANCE

Auto Reset (Sensor) Valve Performance Check

To check the Sensor Valve for proper adjustment and
operation, perform the following procedures.

Failure to chock tires prior to beginning
maintenance could allow vehicle rollaway

which, if not avoided, could result in death or
serious injury.

NOTE:

Apply air system pressure in excess of 85 psig (5.9 bars)

before doing performance check.

1. Disconnect the auto reset (sensor) valve lower linkage connection to

the EDL rod assembly. Rotate valve arm up approximately 20˚ and

hold (FIGURE 19). Air should flow through one-way check valve

ports to air springs (FIG. 19).

2. Move valve arm down 20˚ (FIGURE 20) and hold. Disconnect the

primary height control valve upper linkage connection. Rotate

primary height control valve arm down approximately 45˚ and hold

for 5-10 seconds. Air should flow (exhaust) out top port of auto

reset (sensor) valve (FIGURE 20).

3. Reconnect sensor valve and primary height control valve linkages.

In the event replacement of the
sensor valve is necessary, replace with

sensor valve ONLY. Use of primary height control valve
(1/4˝ [6.35mm] or 3/8˝ [9.53mm] air lines) in place of
sensor valve will result in malfunction of the auto reset
feature and possible damage to suspension and/or trailer.

NOTE:

To prevent side loading on sensor valve linkage

connection—fastening hardware MUST be assembled as

shown in (FIGURE 21) for proper function. If not

assembled as shown, disconnect linkage assembly and

refasten as shown.

Auto

Reset

(Sensor)

Valve

Air should be
flowing out of
both check
valve ports

Air should exhaust
out top port of
sensor valve

Sensor Valve
Arm down 20˚
below horizontal

Disconnect upper
linkage connection

Auto

Reset

(Sensor)

Valve

Primary

Height

Control

Valve

Air

Spring

Hold Primary HCV Arm down
45˚ below horizontal for
10-15 seconds

FIGURE 19

Auto Reset (Sensor) Valve (EDL Engaged) Air Flow
Check

FIGURE 20

Auto Reset (Sensor) Valve Air Flow Check

Disconnect
Lower
Linkage

EDL Rod Assembly

Bottom Port

Valve Arm in up position
(above horizontal)

To Air
Springs

FIGURE 21

Auto Reset Sensor Valve Linkage Assembly

4

3

/

4

˝± 1/8˝

(120.65±
3.18mm)

Must use Nylok
1/4˝- 20 nut (2
places)

Shoulder
Bolt

EDL Rod
Assembly

Flat Washers

Nylok
Nut

Shoulder
Bolt

Sensor

Valve

Nylok Nut

Link - Must
be vertical
to prevent
side loading

Sensor
Valve Arm
Nut Slot

Flat

Washers

Tab

Sensor
Valve
Arm

Tab

Tab